Provisions are made to sense when the battery is
If the battery voltage falls below 10v during glow
will continue, this is considered a failed start. The start
sequence is repeated until the unit starts or three con-
secutive start attempts have failed.
Table 2-10 Battery Voltages
the engine is running and prevents engagement of the
starter motor when operating in auto mode.
cause the engine to be started 30 minutes after the
engine has stopped regardless of the box temperature.
Unit will not cycle off if :
-- battery is less than 13.4 Volts
Unit will restart (overidding minimum off time) if
-- battery drops below 11 Volts
-- coolant temperature drops below 1
continuous mode. If all temperature probes fail and the
RS232 communication port. This port can be used to
communicate unit operating data to a mobile satellite
the office via a modem to a computer.
There are presently three (3) protocols supported.
for the HUGHES transmitter, and Carrier Communica-
tion Protocol. The microprocessor will power up and
transmit a HUGHES protocol packet and continue to
transmit a packet every hour. The microprocessor will
transmit in the Carrier, QualComm protocol if a data
(CPR) ( see Figure 2-1 & Figure 2-2 )
This adjustable regulating valve is installed on the
valve setting is the maximum suction pressure for the
The 2 valves govern cool or heat mode by allowing