EasyManua.ls Logo

Carrier SUPRA 950Mt - Figure 2-13 Compressor Cylinder Heat Unloader Hot Gas Bypass

Carrier SUPRA 950Mt
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
-
2
8
6
2
-
-
6
1
1
X
X
-
-
2
0
(
0
3
/
0
4
)
-
-
water con
tent in the
liqui
d refrige
rant by
color change of the indicator disc.
GREEN means DRY CIRCUIT
YELLOW means WET
CIRCUIT (
in that
case ,
the filter drier must be change ).
2.
9.
7
Fil
te
r d
ri
er
( s
ee
Fig
ur
e 2
-1
& F
igu
re
2-
2 )
Function :
-
-
retain
contami
nants i
n the c
ircuit
-
-
absorb
e hum
idity i
n the
circuit
Insure correct expansion valve operation.
2.
9.
8
Se
rv
ic
e
va
lv
e
Compressors and receiver are equipped with ser-
vice valve for refrigeration circuit maintenance.
Each valve has 3 positions :
Compressor or receiver is isolated from the circuit
FRONT SIDE
POSITION
Refrigerant is in contact with the manifold
connection port.
Normal operation
BACK SIDE POSITION
2.
9.
9
Ho
t
gas
by
pas
s
unl
oad
er
a.
Major W
orking P
arts
1.
Soleno
id and val
ve system
2.
Spring loa
ded pisto
n type bypass contro
l valve
3.
Spring loa
ded disch
arge check val
ve
b.
Unloaded
Operat
ion
Pressure from the
disch
arge manifold (Figure 2-13,
item 15) passes through the strainer (9) and bleed ori-
fic
e
(8
)
to
thebac
k
of
thepis
ton
by
pa
ss
va
lv
e
(7
).
Un
le
ss
bled away, this pressure would tend to close the piston
(6) against the piston spring (5) pressure.
With the solenoid valve (1)
energized
the solenoid
valve stem (2) will
open
the gas bypass port (3).
Re
fri
ge
ra
nt
pre
ss
ure
wi
ll
be
bl
ed
to
the
su
cti
on
ma
n-
ifo
ld
(1
0)
thr
ou
gh
the
op
en
ed
ga
s
by
pa
ss
po
rt
.
A
red
uc
-
tion in pressure on the piston bypass valve will take
pl
ac
e
be
ca
us
e
the
ra
te
of
bl
ee
d
thr
ou
gh
the
ga
s
by
pa
ss
port
is greater than the ra
te of bleed throu
gh the
bleed
orifice
(8)
.
When the pressure behind the piston has been re-
duced sufficiently, the valve spring will force the piston
bypass valve
back
,
opening
the gas bypass from the
discharge manifold to the suction manifold.
Discharge pressure in the discharge manifold will
close the discharge piston check valve assembly (14)
isolating the compressor discharge manifold from the
individual cylinder bank manifold.
The
unloaded
cylinder bank will continue to operate
fully unloaded
until the solenoid valve control device is
de-energized
and the gas bypass port is closed.
10
11
12
13
4
6
5
15
14
1
9
2
3
8
7
1.
Sol
eno
id
val
ve
2.
V
alv
e
Stem
3.
Gas
byp
ass
por
t
4.
Spri
ng
gui
de
5.
Sp
ri
ng
6.
Pi
st
on
7.
Pist
on
byp
ass
valve
8.
Ble
ed
Orifi
ce
9.
Str
ai
ne
r
10.
Suc
tion
Man
ifol
d
1
1.
Cyl
ind
er
discharge valve
12.
V
alv
e
pla
te
13.
Cyl
ind
er
suc
tion
valve
14.
Dis
cha
rge
pis
ton
Check valve
assembly
15.
Dis
cha
rge
man
i
fold
Figure 2-13
Compre
ssor cylinde
r heat unloader
Hot gas bypass