& HGV3) or heating by electric heaters in the evaporator.Heating by hot gas is allowed only if no evaporator is in
will be given inductive heating using the electric heaters in the evaporator.
Both hot gas and electric heat are used for defrost.
When refrigerant vapor is compressed to a high pressure and temperature in a reciprocating compressor, the
mechanical energy necessary to operate the compressor is transferred to the gas as it is being compressed. This
energy is referred to as the “heat of compression” and can be used as the source of heat during the heating cycle.
HGSV3. The normally closed liquid solenoid valves LSV1, LSV2, LSV3 will energize and open. The normally closed
receiver pressure valve (RPV), situated in the hot gas line to the receiver will open. This allows the receiver to be
rized and liquid refrigeran
pass through any liquid line solenoid
s which would be energized. The refrigeran
t passes through the expansion
the required heating. The extra liquid purged from the receiver ensures maximum heating capacity in low ambient
conditions. The evaporator fan passes the air over the hot refrigerant pipes and distributes heated air into the cargo
The hot gas travels through the suctio
n line check valve into the accum
point will then take the lead and revert back to cool/heat cycles.
ple Of Induction Heating (Electr
A control box recuperates the self indicate
electric motor when the unit is driven by the diesel
engine. This current energizes electrical heaters mounted inside the evaporator.
The system includes a control box, connected with electrical cables to the refrigeration unit and to the heaters