30
Menu-GEN.14: Set Hold Canceling Conditions
Function Hold Canceling Conditions Setting
Display Part Meaning
HD-C.00
Hold is canceled when it becomes zero
HD-C.01 Hold is canceled when Hold key is entered
Set Range
(0~2)
HD-C.02 Hold is canceled when Hold less key entered
Menu-GEN.15: Set average hold time
Function Set average hold time
Display Part Meaning
Set Range
(1~99)
HD-T. XX
Initial Value :
30 x 0.1 sec
When the weight change width changes within the automatic hold
range setting value, auto hold operation after set value x 0.1 second.
Menu-GEN.16: Set Auto Hold Range
Function Set auto hold range
Display Part Meaning
Set Range
(5~50)
AH-S. XX
Initial Value :
10 x 1 Digit
Auto hold operation when weight change width is less than
set value. x 1 digit.
Menu-GEN.17: Set Auto Hold Canceling Range
Function Set auto hold canceling range
Display Part Meaning
Set Range
(2~99)
AH-R. XX
Initial Value :
10 %
Auto hold cancel when weight change width is larger than
set value
Menu-GEN.18: Set the use of set key.
Function Set the use of set key
Display Part Meaning
FKEY.00
Set key used as the hold key.
FKEY.01 Set key used as the total print key.
Set Range
(0~2)
FKEY.02 Set key used as the start key.
Menu-GEN.19: Initializing of set values
Function Initializing of set values
Display Part Meaning
INIT. 0
No set values of the product are initialized to factory shipping state
Set Range
(0, 1)
INIT. 1 All set values of the product are initialized to factory shipping state