19
CAL 2
FUNCTION : Minimum division and decimal position setting
Range of set value : 0.001 ~ 50
KEY
DISPLAY
DESCRIPTION
, Key : Value change
ZERO Key : Cancel
SET Key : Save and next menu
1 kg
0.2 kg
0.05 kg
0.001 kg
Note 1. To end CAL2, press CANCEL key when a decimal point is set.
Note 2. Set the external resolution within 1/30,000 as the value by dividing the maximum
weight by the minimum division.
If the external resolution is 1/30,000 or more, Err 21 is shown.
Note 3. The position of a decimal point is decided by the position of a decimal point for the
minimum division set in CAL2.