53
(3) Main Usage of CI-170A (Example 1 - Example 5)
Example 1. Zero Compensation
Display & Key
On platform
Description
Step 1
Empty
Zero point drift.
Step 2
ZERO
Press ZERO key when
the weight is stable.
Step 3
Empty
ZERO compensation:
The present value is
returned
the display to the ZERO.
Note 1. It shall be in zero range to 4% or 10% of maximum capacity in Set menu of
GEN.09.
Note 2. Non-ability in HOLD state of the weight.
Note 3. Non-ability in setting tare.