Menu-4100
Function Set Number of DLC Used
Display Part Meaning
Set Range
(1 ~ 10)
Set Value : XX
Initial Value : 1
Setting the number of DLC Used
(EX _ 1 = Use 1 DLC
(EX _ 8 = Use 8 DLC)
Note 1. Is possible to use up to 10, If you are not connected by the number set to display
Error message.
Menu-4211
Function Set ID of DLC
Display Part Meaning
Set Range
(1 ~ 10)
Set Value : XX
Initial Value : 1
EX _ 1 = Currently connected to the DLC’S ID is set to ‘1’
EX _ 8 = Currently connected to the DLC’S ID is set to ‘8’’
Note 1. When use this function, you will need to connect only a single loadcell.
Menu-4212
Function Set ID automatically(for maintenance)
Display Part Meaning
Set Range
-
-
this function is find the DLC what has no ID,
and set ID to that automatically
Note 1. If you have to replace a loadcell , then use this function.
-First, you need to replace the loadcell. Then you need to run this function.
-The indicator automatically finds a new loadcell and set up new ID to a new loadcell
Note 2. When connect two or more new loadcell, this function should not be running,