10. Serial Data Information
10-1. CAS 22Bytes Format
. . .
DATA (8byte
)
CR LF
└─┘ └──┘ └──────┐ └──┘
US(Unstable) GS(GROSS weight) Device ID Lamp condition byte Empty Unit (kg/t)
ST(Stable) NT(NET weight)
OL(Overload)
Device ID: Send ing1 byte of device ID to selectively receive the information from the indicator to the receiver.
(Device ID is set in F26.)
Data (8 bytes): When the weight date including a decimal, for example, 13.5 kg, 8 bytes of ASCII code
corresponding to 0’,‘0’,‘0’, ‘0’,‘1’,‘3’,‘.’and‘5’ are sent.
Lamp Status Byte
Bt7
1
Bt6
Stable
Bt5
0
Bt4
Hold
Bt3
Printer
Bt2
Gross
Weight
Bt1
Tare
Bt0
Z
ero Poin
t
10-2. CAS 10Bytes
(1) Code: ASCII (2) Transmission data format: (10 bytes)
Data (8 bytes) CR LF
10-3. AND 18bytes
(1) Code: ASCII (2) Transmission data format (18 bytes)
. .
DATA (8byte
)
CR LF
└─┘ └──┘ └──┘
US(Unstable) GS(GROSS weight) Unit (kg/t)
ST(Stable) NT(NET weight)
OL(Overload)