8-3. Communication and Function Setting
Menu-2201
Function Set Device ID
Display Part Meaning
Set Range
(0 ~ 100)
Device ID : ᄋᄋ
Initial Value: 0
Desired device ID may be entered.
Note 1 . This function may be used as the indicator's inherent ID in the COMMAND mode.
Menu-2202
Function Set Data Transmission Rate
Display Part Meaning
Set Range
(1 ~ 9999)
00 x 10ms
Initial Value:
50 x 10ms
Data are transmitted by the unit of 00 x 10ms
Note 1. Data are transmitted in real time upon setting at“0".
Menu-2203
Function Com1 Port Setting
Display Part Meaning
1_Data_8 / Stop_1 /
Parity_none
Data Bit 8, Stop Bit 1, Parity Bit : None
2_Data_7 / Stop_1 /
Parity_even
Data Bit 7, Stop Bit 1, Parity Bit: Even
3_Data_7 / Stop_1 /
Parity_odd
Data Bit 7, Stop Bit 1, Parity Bit: Odd
4_Data_7 / Stop_2 /
Parity_odd
Data Bit 7, Stop Bit 2, Parity Bit: Odd
5_Data_8 / Stop_1 /
Parity_even
Data Bit 8, Stop Bit 1, Parity Bit: Even
Set Range
(1 ~ 6)
6_Data_8 / Stop_1 /
Parity_odd
Data Bit 8, Stop Bit 1, Parity Bit: Odd
59