4 Nomenclature
10
4.2 Display and Indicators
1) VF Display: The front and rear displays on the LP-2 are dot matrix vacuum fluorescent displays.
They will display all information pertinent to operating the scale.
LP-2 Display Window: Sales
1 2 3 4 5 6 7
17
16 8
15
WEIGHT kg
UNIT $ / kg
TOTAL PRICE $
◀
○
◀
<REG> Auto PrePack Shift Ride 12:12:00 PM
This is PLU Commodity Nam
0~30 lb x 0.01 lb / 30~60 lb x 0.02 lb, e=d=0.01 lb, 0.02 lb
0~15 kg x 0.005 kg / 15~30 kg x 0.01 kg, e=d=5g, 10g
ZERO
STABLE
NET
14 13 12 11 10 9
# Description Values
1 Mode indicator REG, RPK, MGR, ADD, PLU, NET
1
, STR
2
,
LOC, SET, X1, X2, Z1, Z2
2 Print Mode indicator Auto
3 Auto Clearing status indicator PrePack, Save, (Blank)
4 Speed key Shift status indicator Shift, (Blank)
5 Override, Frequent Shopper, &
Discount Status
Ride, FSP, DISC, Disc, 1, 2, 3, (Blank)
6 Multi-function indicator Time, date, scale #, department #,
Alt, Temporary Changes, (Blank)
7 PLU Description line First non-blank line of PLU commodity
8 Total price heading TOTAL PRICE and money symbol
9 Total price indicator 7 digits USA: 0.00~9999.99
10 Unit price heading UNIT, money and weigh symbols
11 Unit price indicator 6 digits USA: 0.00~999.99
12 Weight indicator 5 digits
13 Weight heading WEIGHT and weigh symbol
14 Negative weight indicator -, (Blank)
15 Net-Weight indicator ◀, (Blank)
16 Stable weight indicator ○, (Blank)
17 Zero weight indicator ◀, (Blank)
A Gross Zero indication is reached when the Net-Weight indicator is OFF, the Zero-Weight indicator is ON,
the Stable indicator is ON, and the weight reads 0.00 or 0.000.