14 Servicing and Parts Replacement
47
14.1 Platform Safety Overload Adjustment
1. Make sure that the Main Power switch is OFF & that the scale is unplugged.
2. Remove the platter from the platform.
3. Place 1/2 the scale capacity on the right-rear corner of the platform making sure not to obstruct
the Allen-bolt.
4. Adjust the Allen-bolt until it touches the screw underneath it on the upper case.
5. Repeat steps 3 & 4 for the other 3 corners of the platform.
14.2 Removing the Upper Case
1. Make sure that the Main Power switch is OFF & that the scale is unplugged.
2. Remove the platter from the platform & all labels & backing paper from the printer.
3. Remove the display stalk:
A. Unscrew the 2 screws from underneath the column base.
B. Lift & remove the display stalk from the column base.
4. Remove the platform by removing the 4 Allen-bolts on top.