- 28 -
Sealing Mode ::
( G/N KEY - )
STABLE CONDITION
KEY FUNCTION DISPLAY VAL. DESCRIPTION
11
21: Judge if the weight is changed
Within 1 division for 1 sec
Increase or
decrease
set value
~
45: Judge if the weight is changed
Within 2 division for 5 sec
99
99: Judrge if the weight is changed
ENTER
UNIT
Save &
Go to Next
S01 =
Within 4.5division for 9 sec
AUTOMATIC ZERO TRACKING ( 2% of MAX. CAPACITY)
KEY FUNCTION DISPLAY VAL. DESCRIPTION
11
21: Judge if the weight is changed
Within 1 division for 1 sec
Increase or
decrease
set value
:
45: Judge if the weight is changed
99
Within 2 division for 5 sec
99: Judrge if the weight is changed
ENTER
UNIT
Go to initial
CALMod
S02 =
Within 4.5 division for 9 sec
Kg/lb CONVERSION
KEY FUNCTION DISPLAY VAL. DESCRIPTION
0
Not used kg/lb conversion
set value
↓↑
ENTER Go to Next
S03 =
1
Use kg/lb conversion