EasyManua.ls Logo

Cascadia PM Series - Page 29

Cascadia PM Series
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7929 SW Burns Way Phone: 503 344-5085
Suite F
Wilsonville, OR sales@cascadiamotion.com
1/14/2021 RMS PM Hardware User Manual 29 of 54
The RM100 Unit uses the Amphenol PowerLok™ 300 for the high voltage connections.
These connectors utilize the Amphenol RADSOK™ technology. Each connection is a
specific color and keying so that the cables cannot be interchanged.
Inverter
Connection
PowerLok™
Color
PowerLok™ Key
DC+
Red
W
DC-
Black
Y
Phase U
Green
V
Phase V
Orange
X
Phase W
Yellow
U
The housing of the RM100 is marked with the HV Connection designations. The PM
Family of inverters uses the Phase A, B, C designation instead of the RM Family U, V, W.
References in documentation to Phase A refer to Phase U, Phase B to Phase V, and Phase
C to Phase W.
The PowerLok™ 300 is available for many different sizes of wires. Contact Cascadia
Motion for more information about ordering connectors/cables. Please refer to the RM100
HV Connection Manual for more details on how to connect to the RM100.
The RM300 uses the PowerLok™ 500 connector family. Please see the separate RM300
HV connection manual for more information.
The CM200 uses Rosenberger HPK family connectors for making connection to the DC bus
input of the inverter. The HPK family is available in various wires sizes between 16mm
2
and 50mm
2
.

Related product manuals