Signal
1. Hold the System-Master for approx. 1 second in the reading field of the locking device and
then remove it.
The System-Master has been accepted. 1x short green
2. Hold the System-Master once again for approx. 1 second in the reading field of the locking
device and then remove it.
The System-Master is now authorised for this locking device. 1x long green
Troubleshooting:
Signal Cause Solution
After step 1:
4x short red The System-Master
does not have the
correct system
number.
Use the System-Master with the correct system number.
After step 2:
1x short red Another System-
Master has already
been authorised for
this locking device.
Since, at any given time only one System-Master exists
that can be authorised on the basis of its unique system
number for a locking device, there is reason to suspect
manipulation. Contact your CEStronics partner
immediately.
Page 56 of 83 Wide shield replacement handle set ILS-I
11.1 Authorising the System-Master
Overview: Use of master media