11.9 Online mode
11.9.1 Activating online mode
Online mode can only be activated for NET and VA variant locking devices.
Required:
l
RF-Ini-Master (does not require prior authorisation to activate online mode)
Procedure:
Steps
1. Hold the RF-Ini-Master in the reading field of the locking device for 1 second.
One of the following signals appears:
A: 1x short green Connection to Access-Point successful
B: 1x long red Cannot connect to Access-Point
C: 1x long green Connection to Access-Point already exists
Online mode is now active, regardless of whether a connection to an Access-Point could be established. As soon as an Access-
Point is found, the locking device automatically connects to it.
Troubleshooting:
Signal Cause Solution
While the RF-Ini-Master is held in the reading field:
1x long red The locking device is not a NET or VA
variant.
Online mode is not available for these locking
devices.