11.8 Emergency mode
11.8.1 Activating emergency mode
Required:
l
Emergency-Key (must be authorised for the locking device beforehand)
Procedure:
Steps Signal
1. Hold the Emergency-Key in the reading field of the locking device for approx. 1 second.
The Emergency-Key is read and accepted. 1x short green
2. Remove the Emergency-Key from the reading field of the locking device.
The locking device is now in emergency mode. Access is now permanently possible without
the locking media since the locking device remains permanently uncoupled. Emergency
mode can only be deactivated again by an Emergency-Key.
Troubleshooting:
Signal Cause Solution
1x long red The Emergency-Key could be read but is not authorised for this
locking device.
Authorise the
Emergency-Key.
Page 72 of 83 Wide shield replacement handle set ILS-I
11.8 Emergency mode
Overview: Use of master media