11.6.2 Deactivating release mode
Required:
l
Release-Master (must be authorised for the locking device beforehand)
Procedure:
Steps Signal
3. Hold the Release-Master in the reading field of the locking device.
Release mode is deactivated. 2x short green
Release mode is now deactivated.
Troubleshooting:
Signal Cause Solution
1x long red An opening mode with higher priority is currently act-
ive.
Deactivate the
opening mode with the higher pri-
ority.
The Release-Master is not authorised. Authorise the
Release-Master.
Wide shield replacement handle set ILS-I Page 69 of 83
11.6 Release mode
Overview: Use of master media
Help & troubleshooting
Technical data
Maintenance & disposal Operation Administration Assembly Basic information