6
OPERATOR SPECIFICATIONS
This model is intended for use in vehicular slide gate applications:
INTRODUCTION
14.6"
(37.1 cm)
2.85"
(7.2 cm)
10.3" (26.2 cm)
14.6" (37.1 cm)
.63"
(1.6 cm)
10.4" (26.4 cm)
11.9" (30.2 cm)
14.1" (35.8 cm)
21.1"
(53.6 cm)
21.1" (50.8 cm)
Usage Classification
Class I, II, III, & IV
Main AC Supply
120 Vac, 4 Amps (10 Amps including Accessory Outlets)
OR
240 Vac, 2 Amps
When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is
rated 208/240/480/575 VAC, 4.8/4.2/2.1/1.7 A, 60 Hz, 1 PH
System Operating Voltage
24 Vdc Transformer Run / Battery Backup
Accessory Power
24 Vdc, 500mA max. for ON + SW (switched)
Solar Power Max
24 Vdc at 60 watts max.
Maximum Gate Weight
2200 lbs. (997.9 kg)
Minimum Gate Travel Distance
4 feet (1.2 m)
Maximum Gate Travel Distance
50 feet (15.24 m)
Maximum Gate Travel Speed
1 foot/second
Maximum Daily Cycle Rate
Continuous
Maximum Duty Cycle
Continuous
Operating Temperature
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Expansion Board
Provided
Inherent Entrapment Protection (Type A)
Dual - RPM and Current Sense
External Entrapment Protection (Type B1 and/or Type B2)
3 inputs per board - any combination of up to 3 photoelectric sensors and up to
2 edge sensors
MOUNTING FOOTPRINT