INDICATIONS FOR USE
EN
INTELECT
®
RPW 2 USER MANUAL
ADDITIONAL PRECAUTIONS
When administering Radial Pressure Wave treatment, keep
in mind the following:
Radial Pressure Wave treatment should be applied
with caution over bone where minimal (bony
prominence) or no (Stage IV wounds) soft tissue is
present.
Hearing aids should be removed.
The function of other patient connected equipment
may be adversely aected by the operation of the
pulsed radial pressure wave equipment. Maintain
maximum distance between devices in order to
reduce any tendency to interaction. Refer to the
EMC tables at the end of this manual for more
information.
Any bleeding tendency is increased by heating
because of the increase in blood flow and vascularity
of the heated tissues. Care, therefore, should be used
in treating patients with therapeutic Radial Pressure
Wave treatment who have bleeding disorders.
Frequent monitoring of intensity level and skin
response should occur during all treatments.
Always apply the transmitter on the skin with small
circular movements.
Never use Radial Pressure Wave therapy on the head.
Do not treat direct in an area with a metal implant.
Patients with active autoimmune diseases may not
respond positively with the treatment
ADVERSE EFFECTS
Side eects could occur after a treatment with Radial
Pressure Wave therapy. The majority will appear after -
days. Do not repeat a treatment until the previous side
eects have diminished. Common side eects include:
Erythema, reddening
Swelling
Pain
Hematoma
Petechiae, red spots
Skin lesions after previous cortisone therapy
These side eects generally abate after  to  days
PATIENT APPLIED PARTS
Transmitters Material Applied part Type
A Steel .
Type B
T Steel .
Type B
C Ceramic Volcera
Type B
DI  Titan grade  ELI
Type B
F PTFE
Type B
D-S Steel .
Type B
D-S Steel .
Type B
D-T Titan grade  ELI
Type B
Ro Steel .
Type B
R Steel .
Type B
V POM-C LSG ( ACETRON)
Type B
V POM-C LSG ( ACETRON)
Type B
V POM-C LSG ( ACETRON)
Type B
PERI ACTORS POM-C LSG ( ACETRON)
Type B
SPINE ACTORS
Polyvinylidenfluorid EpoFlon –
ECTFE (Halar)
Type B
Ultrasonic gel Water de-ionized water Gel (PH)
Type B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chattanooga Intelect RPW 2 and is the answer not in the manual?

Chattanooga Intelect RPW 2 Specifications

General IconGeneral
BrandChattanooga
ModelIntelect RPW 2
CategoryMedical Equipment
LanguageEnglish

Related product manuals