22
SYSTEM
EN
INTELECT
®
RPW 2 USER MANUAL
OPERATING DATA AND RATINGS
Values displayed on the device are with a tolerance of ±%
Width................................................................................................. mm
Depth ................................................................................................. mm
Height .............................................................................................. mm
Standard Weight (with one handset)....................... Kg lbs
Ambient temperature...................................................... °C - °C
Relative Humidity .................................................................% to %
Air Pressure............................................................ hPa to hPa
Power Consumption
VA (Model DEV)
VA (Model DEV)
VA (Model DEV)
Input
V AC~ Hz VA (Model DEV)
V AC~ Hz VA Model DEV
V AC~ Hz VA
V AC~ Hz VA Model DEV
Output
. bar Hz (RPW) - Hz (V-Actor) (Model DEV)
. bar Hz (RPW) - Hz (V-Actor) Model DEV
. bar Hz (RPW) - Hz (V-Actor) Model DEV
Mode ......................................................................Single or Continuous
Compressed Air Output ..................................................... - . bar
Power Increment Settings ............................................................ bar
Pulse Amplitude.................................approx. mm at bar, idling
(without coupling)
Pulse Width ..................................................................approx. ms
Pulse Frequency......... Hz for RPW, Hz for Vibration
Fuses......................................................... x T.A H V x mm
Electrical Class ................................................................................CLASS I
Electrical Type (Degree of Protection)..................................TYPE B
Regulatory Risk Class..............IIa according to MDD //EEC
Mass........................................................................................ Kg ( lbs)
Safe Working Load................................................................. Kg ( lbs)
FALCON HANDPIECE TECHNICAL
SPECIFICATIONS
Compressed air input........................................................... - . bar
Ambient temperature during operation........................ - °C
Ambient temperature during storage.............................. - °C
and transport
Ambient air pressure during operation.............. - , hPa
Ambient air pressure during storage................... - , hPa
and transport
Air humidity Storage............................... - %, non-condensing
and transport
Air operation............................................... - %, non-condensing
Weight.................................................................................................... g
SOFTWARE
The software is developed and provided by DJO.
To view the version of the software, press the Settings
button. The version number of the Software can be found
by pushing the display unit version information.
TRANSPORT AND STORAGE CONDITIONS
Ambient temperature.................................................. °C - °C
Relative Humidity..............................% % no condensation
Air Pressure ........................................................... hPa to hPa