Defines the specific applications for which the freeze-dryer is designed and warns against improper use.
Details the sequence of steps involved in the freeze-drying process: preparation, freezing, main drying, and final drying.
Outlines the obligations of the operator to ensure personnel safety and proper unit handling.
Specifies the requirements for individuals operating the freeze-dryer.
Lists essential safety precautions to be observed before and during every drying process.
Details safety measures related to the electrical system, including voltage matching and equipment inspection.
Provides guidelines for safe mechanical operation, including avoiding damage and using approved accessories.
Outlines precautions to prevent fire hazards, including fuse usage and avoiding explosive substances.
Warns about the cold temperatures of the ice condenser and the need for protective gloves.
Covers safety measures for handling infectious, toxic, or radioactive substances during drying.
Provides step-by-step instructions for handling electrical incidents, fires, electric shocks, and burns.
Details the mandatory environmental and location requirements for operating the freeze-dryer.
Covers electrical connection requirements, safety class, and customer-provided fuses.
Details the connection and operation of the vacuum pump, including exhaust filter recommendations.
Introduces the LSCplus control system and its user interface for intuitive operation.
Explains the touch panel operation and the four main windows: Manual, Program, Options, and ?.
Details the Manual window, showing process data and allowing manual control of freeze-drying phases.
Describes the Program window for creating, loading, and editing freeze-drying programs.
Covers the Options window for fundamental settings like language, scale units, and freeze-drying process selection.
Explains how to switch between freeze-drying phases manually and define set values.
Explains the PGMplus module for automatic and reproducible freeze-drying processes.
Guides through the process of creating new freeze-drying programs using templates or from scratch.
Explains how to load a saved program to control the freeze-drying process.
Lists common errors like no display, touchpanel issues, password failure, and insufficient vacuum.
Details causes and solutions for insufficient vacuum, including flange connections and valve issues.
Explains potential causes for insufficient ice condenser temperature and protective device tripping.
Provides contact information for service inquiries, malfunctions, and spare part requests.
Emphasizes the importance of thorough maintenance for extending service life and preventing failures.
Provides maintenance recommendations for the vacuum pump, including oil level checks and oil changes.
Recommends using specific disinfectants and contacting the manufacturer before using others.
Warns about risks during service work and recommends annual checks by the manufacturer.
Details electrical, protection class, power, current, and fuse requirements for connection.
| Condenser temperature | -85°C |
|---|---|
| Control system | LSCplus controller |
| Type | Laboratory freeze dryer |
| Capacity | 2-4 kg |
| Cooling system | Air-cooled |
| Shelf temperature range | -55°C to +60°C |
| Weight | 150 kg |
| Power supply | 230 V, 50 Hz |