Automatic Transformer Test System 3300/3302 Users Manual
2-6
2.7 List Sweep (3302 only)
A maximum of 9 frequencies or test signal levels can be programmed. Single or
sequential test can be performed.
2.8 Comparator Function (3302 only)
Ten bin sorting for the primary measurement parameter, and IN/OUT decision
output for the secondary measurement parameter.
Sorting Modes:
Sequential mode: Sorting into unnested bins with absolute upper and lower limits.
Tolerance mode: Sorting into nested bins with absolute or percent limits.
Bin Count:
0 to 999999
List Sweep Comparator:
HIGH/PASS/LOW decision output for each point in the list sweep table.
2.9 Interfaces
Printer Interface : Standard Printer Interface.
RS-232 Interface : Standard RS-232 Interface.
Handler Interface: PASS/FAIL/Ext Trig.
2.10 Others
Display : 320x240 Graphic LCD Display.
Power: 100V
120V AC, 50Hz/60Hz. Power consumption is 140VA, maximum.
220V
240V AC, 50Hz/60Hz. Power consumption is 140VA, maximum.
Environment : Operating -- 0
to 40
, 10 to 85% relative humidity.
Storage -- -10
to 50
, 10 to 90% relative humidity.
Dimensions : 430(W) x 177(H) x 300(D)
Weight : 8.5Kg.