EasyManuals Logo

Chroma 6430 User Manual

Chroma 6430
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
Remote Operation
Bit configuration of Questionable Status Register
Bit
Position
8-15 7 6 5 4 3 2 1 0
Condition --- FAN OPP OCP SHT OTP UVP OPEN PFO
Bit Weight 128 64 32 16 8 4 2 1
Remarks: FAN : Fan failure OCP : Over current protection
OTP : Over temperature protection SHT : Short circuit protection
UVP : Under voltage protection PFO : Power failure protection
OPP : Over power protection OPEN : Open circuit protection
STATus:QUEStionable?
Description: This query returns the content of the Questionable Event Register. The
Questionable Event Register latches events that are passed by Questionable
PTR and/or NTR filter. It is cleared when read or by the *CLS common
command.
Query Syntax: STATus:QUEStionable[:EVENt]?
Parameters: None
Return Parameters: <NR1>
Query Example: STAT:QUES? It returns and clears the Questionable Event Register.
STATus:QUEStionable:CONDition?
Description: This query returns the content of the Questionable Condition Register. The
Questionable Condition Register reflects the TRUE or FALSE state of
Questionable status.
Query Syntax: STATus:QUEStionable:CONDition?
Parameters: None
Return Parameters: <NR1>
Query Example: STAT:QUES:COND? It returns the Questionable Condition Register.
STATus:QUEStionable:ENABle
Description: This command sets the enable mask which allows true conditions in the
Questionable Event Register to be reported in the Questionable Status (QUES)