INSTALLATION
60
Table 4-2: Tundra Water Usage
Table 4-3: Single Stage Water Usage
°F °C °F °C GPM LPH GPM LPH GPM LPH PSID bar
85.00 29.44 13.12 2,987.64 21.45 4,886.39 32.68 7,443.34 40.00 2.76
80.00 26.67 8.74 1,991.76 14.30 3,257.59 21.78 4,962.23 37.50 2.59
75.00 23.89 6.56 1,493.82 10.73 2,443.19 16.34 3,721.67 35.00 2.41
70.00 21.11 5.25 1,195.06 8.58 1,954.55 13.07 2,977.34 32.50 2.24
65.00 18.33 4.37 995.88 7.15 1,628.80 10.89 2,481.11 30.00 2.07
60.00 15.56 3.75 853.61 6.13 1,396.11 9.34 2,126.67 27.50 1.90
55.00 12.78 3.28 746.91 5.36 1,221.60 8.17 1,860.83 25.00 1.72
50.00 10.00 2.91 663.92 4.77 1,085.86 7.26 1,654.08 22.50 1.55
45.00 7.22 2.62 597.53 4.29 977.28 6.54 1,488.67 20.00 1.38
154,385.64
1.00"
REQUIRED FLUID
PRESSURE DIFFERENTIAL
101,350.72
1.00"
WATER FLOW RATE
INLET
OUTLET
6-SCT/WC
WATER TEMPERATURE
10-SCT/WC
WATER FLOW RATE
15-SCT/WC
WATER FLOW RATE
95.00
35.00
WATER HEAT LOAD (BTU/hr)
WATER CONNECTION (NPT)
61,968.02
0.75"
°F °C °F °C GPM LPH PSID bar
85.00 29.44 6.83 1,554.84 40.00 2.76
80.00 26.67 4.55 1,036.56 37.50 2.59
75.00 23.89 3.41 777.42 35.00 2.41
70.00 21.11 2.73 621.94 32.50 2.24
65.00 18.33 2.28 518.28 30.00 2.07
60.00 15.56 1.95 444.24 27.50 1.90
55.00 12.78 1.71 388.71 25.00 1.72
50.00 10.00 1.52 345.52 22.50 1.55
45.00 7.22 1.37 310.97 20.00 1.38
WATER FLOW RATE
INLET
OUTLET
2-H/WC
WATER TEMPERATURE
REQUIRED FLUID
PRESSURE DIFFERENTIAL
WATER HEAT LOAD (BTU/hr)
WATER CONNECTION (NPT)
95.00
35.00
32,249.71
0.75"

Table of Contents