OFF 9
OFF 10
OFF 14
OFF 16
OFF 17
OFF 24A
OFF 24B
OFF 31A
OFF 31B
OFF 31C
OFF 33A, B, C
there is a control for the maximum grinding time; after this
threshold has been exceeded, error 9 is produced; no coffee,
hopper orange blade closed; wear, grinders excessively closed;
the values written in the EAROM are not compatible with the
operation of the machine or deleted; reload them; replace the CPU
board CPU; (see 05.39.a.);
there is a control causing the machine to reload water after a well-
defined number of dispensing cycles; otherwise, error 14 is
produced; make sure that the water supply from the outside is
correct (see 03.03.) and that the water circuit of the machine is
orderly (tubes, gaskets, …);
check the display board (see 05.39.b.);
a key of the selection keyboard is not operating (short-circuited); it
may also occur if an operator should operate it for too long while
programming the machine (keys 4 and 5 to increase and decrease
the quantities); (see 05.02. e 09.01.a.);
the 24 V dc power supply should exceed the limit value; replace
the
CPU board (see 05.39.a.);
after al long inactivity, if this error happens, could be enough to
switch off and switch on the machine; if the power failure persists,
pay attention to the cause: a 24 V actuator could be faulty (mixer
or product motor, water inlet electrovalve, …); check the alternate
power supply at the board input; the voltage regulator might be
faulty; replace the CPU board (see 05.39.a.);
the pressure boiler temperature has exceeded the one you have
programmed (see 09.01.e.); replace the temperature probe; the
device of the CPU board is not working according to control;
replace the CPU board;
temperature safety devices tripped (clicsons,, …); restore or
replace them; heating element not supplied or not operating; check
the connections and continuity of the heating element; if
necessary, replace it;
temperature probe interrupted; connector to the board, wiring;
make sure that the cable between the probe and the CPU board is
not interrupted or replace the probe;
they have the same meaning of errors 31A,
B e C, but referred to I
machines;
grinding time too
long
(E machines)
loss of programming
data
no water reload
display board
selection keyboard out
of order
24 V dc power supply
excessive
24 V dc power supply
inadequate or lacking
water temperature
high
(E machines)
water temperature low
(E machines)
temperature probe
(E machines)
(I machines)
cino eC by
MAN1010105 rel. 03 dated 12.02.2014 page no. 43 of 50 page
www.rheavendors.com tel: 0039 02 966 551 fax: 0039 02 96 55 086 e mail: rheavendors@rheavendors.com