20
Enter Setup
1000/1090+/1100/1105 Barcode Scanner
User Guide
1.4.4 AUTO OFF MODE
The scanner will start scanning once the trigger is pressed.
The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout
expires.
Note: Refer to “Scanning Timeout”.
Auto Off Mode
Note: By default, the scan mode of 1000 and 1090+ is set to Auto Off mode.
1.4.5 AUTO POWER OFF MODE
The scanner will start scanning once the trigger is pressed.
The scanning won't stop until the pre-set timeout expires, and, the pre-set timeout
period re-counts after each successful decoding.
Note: Refer to “Delay between Re-read” and “Scanning Timeout”.
Auto Power Off Mode
1.4.6 ALTERNATE MODE
The scanner will start scanning once the trigger is pressed
The scanning won't stop until you press the trigger again.
Alternate Mode

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CipherLab 1105 and is the answer not in the manual?

CipherLab 1105 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength630 nm
Sensor typeLaser
Read rate (max)100 reads/s
Pitch reading angle-70 - 70 °
Optical sensor resolution3648 pixels
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, GS1-128 (UCC/EAN-128), MSI, Pharmacode, Plessey, Telepen, U.P.C.
2D (matrix & stacked) barcodes supported-
Connectivity technologyWired
Product colorGray
Housing materialPolyurethane
Power consumption (standby)0.06 W
Power consumption (typical)0.190 W
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth145 mm
Width93 mm
Height64 mm
Weight165 g