197
Appendix II Symbology Parameters
Values (N2%) & Description
74 1: Enable GS1 DataBar Limited
0: Disable GS1 DataBar Limited
0 CCD, Laser
8700 –
Range
75 Reserved --- ---
76 1: Enable GS1 DataBar Omnidirectional &
Expanded
0: Disable GS1 DataBar Omnidirectional &
Expanded
0 CCD, Laser
8700 –
Range
77 1: Transmit GS1 DataBar Omnidirectional Code ID
0: DO NOT transmit GS1 DataBar Omnidirectional Code ID
1 CCD, Laser
8700 –
Range
78 1: Transmit GS1 DataBar Omnidirectional Application ID
0: DO NOT transmit GS1 DataBar Omnidirectional
Application ID
1 CCD, Laser
8700 –
Range
79 1: Transmit GS1 DataBar Omnidirectional Check Digit
0: DO NOT transmit GS1 DataBar Omnidirectional
Digit
1 CCD, Laser
8700 –
Range
80 1: Transmit GS1 DataBar Limited Code ID
0: DO NOT transmit GS1 DataBar Limited Code ID
1 CCD, Laser
8700 –
Range
81 1: Transmit GS1 DataBar Limited Application ID
0: DO NOT transmit GS1 DataBar Limited Application ID
1 CCD, Laser
8700 –
Range
82 1: Transmit GS1 DataBar Limited Check Digit
0: DO NOT transmit GS1 DataBar Limited Check Digit
1 CCD, Laser
8700 –
Range
83 1: Transmit GS1 DataBar Expanded Code ID
0: DO NOT transmit GS1 DataBar Expanded Code ID
1 CCD, Laser
8700 –
Range
175 Enable GS1 formatting for GS1 DataBar Family
1: Enable
0: Disable
0 CCD, Laser
8700 –
Range
Decide whether or not to include the Code ID (“]e0”) in the data being transmitted.
Decide whether or not to include the Application ID (“01”) in the data being transmitted.
Decide whether or not to include the check digit in the data being transmitted.