Using RS35 Mobile Computer
BATTERY TEMPERATURE ANOMALY
High ambient temperature or keeping using RS35 mobile computer while charging might
result in battery temperature rises. RS35 mobile computer will automatically suspend
charging battery or shut down for safety purpose. Once the battery temperature cools
down to normal temperature, battery charging could be proceeded again.
The warning “Over Battery Temperature” shows up to instruct you to remove the battery
if the temperature of the RS35 battery reaches 55 while it prompts to automatically shut
down if the temperature of the RS35 battery reaches 60 .
Using RS35 mobile computer under low-temperature environment may cause the device
shut down automatically. If the battery temperature is at 0 or even lower than 0 while
charging, the red Status LED in the front panel blinks with a warning window popup to
remind the user to disconnect the charger, and RS35 mobile computer will automatically
suspend charging the battery.
For battery life, please unplug the charger immediately and charge your RS35 mobile
computer under appropriate temperature conditions.