----- Supply network analyzer CVM 96 Ethernet -------- ----- Page No. 31
Mechanical Characteristics :
- Connection : pluggable connection terminal
- Case material Self-extinguishable, V0 plastic
- Protection Assembled unit (frontal ) : IP 54
Un-assembled unit (side and rear covers) : IP 31
- Dimensions 96 x 96 mm - depth: 100 mm
- Weight 0.520 kg
Relays characteristics: according to model
- Maximum switching load : 750 VA
- Maximum switching voltage : 250 V a.c.
- Maximum switching current : 3 A (Resistive)
- Mechanical endurance : 3 x 10
7
operations
- Energy / alarms pulses : max. 1 pulse / s
At full load: (250 V a.c. / 3 A )
- Electrical endurance : 1 x 10
5
operations
- Maximum operation cadence : 450 oper. / hour
- Safety .............. Category III - 300 V a.c. / 520 a.c., as per EN-61010
- Protection against electric shock by class II double-isolation
Standards : IEC 664, VDE 0110, UL 94 , IEC 801 , IEC 348 , IEC 571-1
EN 50081-1, EN 50082-1 , EN-61010-1