Raption
72 Service Manual
CHARGEPOINT LEVEL
Error Hexadecimal Decimal Description
OK 0x0 0 No error
CFG 0x1 1 Invalid Configuration
READER 0x2 2 Reader Error.
DISPLAY 0X4 4 Display Error.
TAMPER 0x8 8 Tamper Error.
TILT 0x10 16 Charge point is tilted.
SUPPLY 0X20 32 Power Supply dropped.
RCD 0X40 64 RCD dropped.
TEMPERATURE 0x80 128 Temperature out of range
OTHER 0x100 256 Other error not defined above.
COMMUNICATION 0x200 512
One or more devices configured on the
charge point are not communicating.
TYPE 0X400 1024
Device installed is not the same as
configured.
VERSION 0x800 2048 Incorrect device version.
GROUND 0x1000 4096 PE error.
MCB 0x2000 8192 Charge Point MCB tripped
OFFLINE 0x4000 16384 Charge point is offline