Service Manual 73
  
Raption 
PLUG LEVEL
Error Hexadecimal Decimal  Description
OK 0x0 0  No error.
CFG 0x1 1  Invalid Configuration.
MASTER 0x2 2
Charge Point error. Plug is inoperative. 
Check    Charge point error affected.
USER_INTERFACE 0X4 4  User Interface error.
LOCK 0x8 8  Lock error.
SUPPLY 0x10 16  Power supply dropped.
RCD 0X20 32  RCD tripped
CONTACTOR 0X40 64  Contactor failed.
METER 0x80 128  Meter failed.
EMERGENCY 0x100 256  Emergency button pressed.
TEMPERATURE 0x200 512  Temperature out of range.
EV_
COMMUNICATION_
DEVICE
0X400 1024
Communication between charge point 
and vehicle failed.
EV_CORD 0x800 2048  Proximity pin error. (Mode 3)
OTHER 0x1000 4096  Other error not defined above.
COMMUNICATION 0x2000 8192
One or more devices configured on the 
socket are not communicating.
OVERCURRENT 0x4000 16384  Current consumption exceeded.
MCB 0x8000 32768  MCB tripped
VOLTAGE 0x10000 65536  Voltage out of range.
SOCKET 0x20000 131072
All sockets contained by the plug are in 
error  state. Plug is inoperative. Check 
sockets affected.
TAMPER 0x40000 262144  Tamper Error