Raption
74 Service Manual
SOCKET LEVEL
Error Hexadecimal Decimal Description
OK 0x0 0 No error.
CFG 0x1 1 Invalid Configuration.
MASTER 0x2 2
Plug error. Socket is inoperative. Check
plug error affected.
USER_INTERFACE 0X4 4 User Interface error.
LOCK 0x8 8 Lock error.
SUPPLY 0x10 16 Power supply dropped.
RCD 0X20 32 RCD tripped
CONTACTOR 0X40 64 Contactor failed.
METER 0x80 128 Meter failed.
EMERGENCY 0x100 256 Emergency button pressed.
TEMPERATURE 0x200 512 Temperature out of range.
EV_
COMMUNICATION_
DEVICE
0X400 1024
Communication between charge point
and vehicle failed.
EV_CORD 0x800 2048 Proximity pin error. (Mode 3)
OTHER 0x1000 4096 Other error not defined above.
COMMUNICATION 0x2000 8192
One or more devices configured on the
socket are not communicating.
OVERCURRENT 0x4000 16384 Current consumption exceeded.
MCB 0x8000 32768 MCB tripped
VOLTAGE 0x10000 65536 Voltage out of range.