Notifying Boot - 200
CS should check if charger is added in their side.
Check charge point ID whithin OCPP configuration on CP side. http://ip_address:8080/
html/setup.html
Notifying Boot - -1
There is some kind of filter on the network related with the size of the messages sent
from the charger, maybe in the simcard provider side or in the CS. This filter cause
that the message, or part of the message is not sent to the CS, so information is not
completely delivered. That problem can be solved adjusting the MTU to a lower value.
Default value is 1500, and a good solution would be to adjust it to 1000 or 1200 bytes.
In this way problem is solved as messages size is lower than the filter.
Raption / eVolve Master:
• Teltonika RUT240 allows you to adjust this paramter in the Network→Mobile
section.
• Ask Simcard provider to adjust the MTU value to 1000 or 1200 bytes.
Evolve / WB Smart:
• Ask Simcard provider to adjust the MTU value to 1000 or 1200 bytes.
HTTP/1.1 404 Not Found
Charger reaches the CS and could not logged in:
The Host URL introduced is not correct. Please, review and make sure it is properly
written. Take into account that it is case sensitive:
http://ip_address:8080/html/setup.html