EasyManuals Logo

Circutor Raption Series User Manual

Circutor Raption Series
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
Raption
101Instruction Manual
Parameter Description
Use OCPP time
synchronization
Enabled: Synchronization of date and time
Disabled: Synchronization of date and time
Note: Date and Time is sent from backend on each heartbeat response.
Energy for Start/
Stop transaction
Partial: Consumed value of energy by the vehicle sent between start
and stop.
Total: Actual count of the total accumulated energy meter sent be-
tween start and stop.
Energy for
metervalues
Partial: Sends partial energy consumption while vehicle is charging.
Total: sends the actual count of the total accumulated energy meter.
User confirmation
required to start
transaction
Enabled: user confirmation needed to proceed with a remote start (i.e.
touch the screen)
Disabled: user confirmation NOT needed to proceed with a remote start
ID tag endianness Storage type for system data (BIG or LITTLE)
Send metervalues
only while charging
Choose between (ENABLED or DISABLED)
Log capture level Level of information detailed (DEBUGINFOERRORNONE)

Other manuals for Circutor Raption Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Circutor Raption Series and is the answer not in the manual?

Circutor Raption Series Specifications

General IconGeneral
BrandCircutor
ModelRaption Series
CategoryBattery Charger
LanguageEnglish

Related product manuals