Status and Statistics
RMON
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4 79
5
To enter RMON alarms:
STEP 1 Click Status and Statistics > RMON > Alarms.
All previously-defined alarms are displayed. The fields are described in the Add RMON
Alarm page below. In addition to those fields, the following field appears:
Counter Value—Displays the value of the statistic during the last sampling period.
STEP 2 Click Add.
STEP 3 Enter the parameters.
Alarm Entry—Displays the alarm entry number.
Interface—Select the type of interface for which RMON statistics are displayed.
Counter Name—Select the MIB variable that indicates the type of occurrence
measured.
Sample Type—Select the sampling method to generate an alarm. The options are:
- Absolute—If the threshold is crossed, an alarm is generated.
- Delta—Subtracts the last sampled value from the current value. The difference in
the values is compared to the threshold. If the threshold was crossed, an alarm is
generated.
Rising Threshold—Enter the value that triggers the rising threshold alarm.
Rising Event—Select an event to be performed when a rising event is triggered. Events
are configured in the RMON Events Control page.
Falling Threshold—Enter the value that triggers the falling threshold alarm.
Falling Event—Select an event to be performed when a falling event is triggered.
Startup Alarm—Select the first event from which to start generation of alarms. Rising
is defined by crossing the threshold from a low-value threshold to a higher-value
threshold.
- Rising Alarm—A rising value triggers the rising threshold alarm.
- Falling Alarm—A falling value triggers the falling threshold alarm.
- Rising and Falling—Both rising and falling values trigger the alarm.
Interval—Enter the alarm interval time in seconds.

Table of Contents

Other manuals for Cisco 350 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 350 Series and is the answer not in the manual?

Cisco 350 Series Specifications

General IconGeneral
ModelCisco 350 Series
CategorySwitch
Ports8, 24, 48
PoEAvailable on some models
LayerLayer 2
Switching CapacityUp to 104 Gbps
VLAN SupportYes (up to 256 VLANs)
QoSYes
ManagementWeb, CLI, SNMP
Security FeaturesACLs, 802.1X, Port Security
Jumbo Frame SupportYes
Power SupplyInternal
DimensionsVaries by model
WeightVaries by model
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
Humidity10% to 90% non-condensing
Port TypeGigabit Ethernet, Fast Ethernet (depending on model)