EasyManua.ls Logo

Cisco Catalyst 9500

Cisco Catalyst 9500
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DescriptionAttribute
Cisco IOS XE Gibraltar 16.10.1.Intitial release
Displays a syslog message if the test fails for a port.Corrective action
All modules.Hardware support
TestFantray
This test verifies if the fan tray has been inserted, and is working properly on the board. This test runs every
100 seconds.
DescriptionAttribute
NondisruptiveDisruptive or Nondisruptive
Do not disable. This can be run as a health-monitoring
test and also as an on-demand test.
Recommendation
On.Default
Cisco IOS XE Fuji 16.8.1.Intitial release
Displays a syslog message if the fan tray is not present
or any of the fans fail.
Corrective action
All modules.Hardware support
TestPhyLoopback
This PHY loopback test verifies the PHY-level loopback functionality. In this test, a packet, which loops back
at the PHY level and is matched against the stored packet, is sent. It cannot be run as a health-monitoring test.
DescriptionAttribute
Disruptive.Disruptive or Nondisruptive
Run this as an on-demand test as per requirement.Recommendation
Off.Default
Cisco IOS XE Fuji 16.8.1.Intitial release
Displays a syslog message if the test fails for a port.Corrective action
All modules.Hardware support
TestThermal
This test verifies the temperature reading from a device sensor if it is below the yellow temperature threshold.
This test runs every 90 seconds.
System Management Configuration Guide, Cisco IOS XE Amsterdam 17.2.x (Catalyst 9500 Switches)
197
Configuring Online Diagnostics
Generic Online Diagnostics (GOLD) Tests

Table of Contents

Other manuals for Cisco Catalyst 9500

Related product manuals