Fan 4: Normal
Fan 5: Normal
Reporting Functions
The chassis manager on the forwarding engine control processor manages the local resources of the forwarding
processor. The controller displays warning messages on the console, if the chassis interface-monitored
parameters exceed a threshold. You can also retrieve and display environmental status reports with the following
commands:
show environment all
show version
show inventory
show platform
show platform software status control-processor
show diag
Parameters are measured and reporting functions are updated every 60 seconds. A brief description of each
of these commands follows.
show environment all command
The show environment all command displays temperature, voltage, fan, and power supply information.
show version Command
The show version command displays the system hardware configuration, software version, and names and
sources of configuration files and boot images.
show inventory Command
The show inventory command displays an extended report that includes the product inventory listing of all
the Cisco products installed in the networking device.
show platform Command
The show platform command displays platform information.
show platform software status control-processor Command
The show platform software status control-processor command displays the average load, memory usage,
and CPU utilization levels at which the controller is running. The output also specifies whether the levels of
these system health parameters are within defined thresholds.
show diag chassis eeprom detail Command
The show diag chassis eeprom detail command displays the configuration hardware information, including
power or fan module P0 and P1 EPPROM data.
Cisco Catalyst CW9800H1 and CW9800H2 Wireless Controllers Hardware Installation Guide