TypicalMaximumQuantityComponent
——1 to 8 (can mix
types)
F2 I/O Modules
451 W500 W48-port 1- and 10-Gigabit Ethernet I/O
module (N77-F248XP-23E)
——F3 I/O Modules
450 W
480 W48-port 1- and 10-Gigabit Ethernet I/O
module (N77-F348XP-23)
650 W740 W24-port 40-Gigabit Ethernet I/O module
(N77-F324FQ-25)
640 W730 W12-port 100-Gigabit Ethernet I/O module
(N77-F312CK-26)
——F4 I/O Modules
730 W
1000 W30-port 100-Gigabit Ethernet I/O module
(N77-F430CQ-36)
——M3 I/O Modules
500 W
560 W48-port 1- and 10-Gigabit Ethernet I/O
module (N77-M348XP-23L)
700 W750 W24-port 40-Gigabit Ethernet I/O module
(N77-M324FQ-25L)
800 W1095 W12-port 100-Gigabit Ethernet I/O module
(N77-M312CQ-26L)
122 W150 W3 to 6Fabric Modules (N77-C7710-FAB-2)
120 W150 W3 to 6Fabric Modules (N77-C7710-FAB-3)
———Fan Trays
44 W
600 W338 mm Gen 1 Fan Tray (N77-C7710-FAN)
44 W600 W376 mm Gen 2 Fan Tray
(N77-C7710-FAN-2)
Maximum Power Available for 3-kW AC Power Supplies
The maximum power available for operations depends on the input power from your power source, the number
and output capabilities of your power supplies, and the power redundancy mode that you use. The following
table lists the amount of power available for 3-kW power supplies depending on power inputs, numbers of
power supplies, and the mode used.
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
141OL-30452-01.
Switch Specifications
Maximum Power Available for 3-kW AC Power Supplies