xbar-1 Outlet (s1) 125 125 38 Ok
xbar-1 Intake (s2) 60 42 32 Ok
xbar-1 Crossbar(s3) 105 95 56 Ok
xbar-2 Outlet (s1) 125 125 39 Ok
xbar-2 Intake (s2) 62 42 31 Ok
xbar-2 Crossbar(s3) 105 95 56 Ok
switch#
Connecting to a Module
At any time, you can connect to any module by using the attach module command. Once you are at the
module prompt, you can obtain further details about the module by using module-specific commands in EXEC
mode.
You can also use the attach module command to display the standby supervisor module information, although
you cannot configure the standby supervisor module using this command.
Step 1 Enter the attach module slot_number command.
Example:
switch# attach module 4
switch(standby)#
Provides direct access to the specified module (in this example, the standby supervisor module is in slot 6).
Step 2 dir bootflash
Example:
switch(standby)# dir bootflash
Example:
switch# dir bootflash:
80667580 Feb 21 22:04:59 2008 n7700-s2-kickstart.7.3.0.DX.1.bin
22168064 Feb 21 22:04:19 2008 n7700-s2-dk9.7.3.0.DX.1.bin
16384 Jan 03 19:56:00 2005 lost+found/
Usage for bootflash://sup-local
234045440 bytes used
1684602880 bytes free
1918648320 bytes total
switch#
Provides the available space information for the standby supervisor module.
To exit the module-specific prompt, use the exit command.
Note
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
59OL-30452-01.
Managing the Switch
Connecting to a Module