Transmit and Receive
Wavelength (nm)
Receive Power (dBm)Transmit Power (dBm)Transceiver TypeTransceiver
1260 to 1355 nm0.5 (maximum per lane)
-8.4 (minimum per lane)
(in average)
-6.4 (minimum per lane)
(in OMA)
7
0.5 (maximum per lane)
-6.5 (minimum per lane)
10GBASE-LRM,
1310-nm SMF
SFP-10G-LRM
840 to 860 nm0.5 (maximum per lane)
-8.2 (minimum per lane)
–1.2 (maximum per
lane)
8
–7.3 (minimum per lane)
10GBASE-SR, 850-nm
MMF
SFP-10G-SR
7
Both the average and the OMA specifications must be met simultaneously.
8
The launch power shall be the lesser of the class 1 safety limit or the maximum receive power. Class 1 laser requirements are
defined by IEC 60825-1:2001.
For the environmental specifications, see the following table.
SpecificationParameter
–40 to 185°F (–40 to 85°C)Storage temperature
32 to 158°F (0 to 70°C)Operating temperature
–40 to 158°F (–40 to 70°C)Case temperature
3.1 to 3.5 VModule supply voltage
10BASE-DWDM SFP+ Transceiver Specifications
The Dense Wavelength Division Multiplexing (DWDM) SFP+ transceivers are part of a DWDM optical
network to provide high-capacity bandwidth across a fiber-optic network. There are 32 fixed-wavelength
DWDM SFP+ transceivers that support the International Telecommunications Union (ITU) 100-GHz
wavelength grid. These transceivers have duplex SC connectors. DWDM SFP+ transceivers can transmit and
receive optical signals up to 50 miles (80 km) depending on the quality of the fiber-optic cable used.
DWDM SFP+ transceivers look like the typical 10GBASE-X SFP+ transceivers as shown in the following
figure.
Figure 34:
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.166
Switch Specifications
10BASE-DWDM SFP+ Transceiver Specifications

Table of Contents