Table 13:
Transmit and
Receive Wavelength
(nm)
Receive Power
(dBm)
Transmit Power
(dBm)
Transceiver TypeTransceiver
840 to 860 nm2.4 (maximum per
lane)
-5.2 (minimum per
lane)
2.4 (maximum per
lane)
-8.4 (minimum per
lane)
QSFP+QSFP-100G-SR4-S
Four lanes: 1295,
1300, 1304, 1309
4.5 (maximum per
lane)
-8.6 (minimum per
lane)
4.5 (maximum per
lane)
-4.3 (minimum per
lane)
QSFP+QSFP-100G-LR4-S
Four lanes: 1271,
1291, 1311, 1331
2.5 (maximum per
lane)
-10 (minimum per
lane)
2.5 (maximum per
lane)
-6.5 (minimum per
lane)
QSFP+QSFP-100G-CWDM4-S
1295 to 13252 (maximum per
lane)
-26 (minimum per
lane)
2.9 (maximum per
lane)
-9.4 (minimum per
lane)
QSFP+QSFP-100G-PSM4-S
855, 9084 (100G), 5 (40G)
(maximum per lane)
-7.9 (100G), -6
(40G) (minimum per
lane)
+4 (100G), +5 (40G)
(maximum per lane)
-6 (100G), -4 (40G)
(minimum per lane)
QSFP+QSFP-40/100G-SRBD
For the environmental specifications, see the following table.
SpecificationParameter
–40 to 185°F (–40 to 85°C)Storage temperature
32 to 158°F (0 to 70°C)Operating temperature
–40 to 158°F (–40 to 70°C)Case temperature
5 to 95 percentStorage relative humidity
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
159OL-30452-01.