IP Version—Select either IPv4 or IPv6.
IPv6 Address Type—Select the IPv6 address type (if IPv6 is used). The
options are:
- Link LocalThe IPv6 address uniquely identifies hosts on a single
network link. A link local address has a prefix of FE80, is not routable, and
can be used for communication only on the local network. Only one link
local address is supported. If a link local address exists on the interface,
this entry replaces the address in the configuration.
- GlobalThe IPv6 address is a global Unicast IPV6 type that is visible and
reachable from other networks.
Link Local Interface—Select the link local interface (if IPv6 Address Type
Link Local is selected) from the pull-down list.
Recipient IP Address/Name—Enter the IP address or server name of
where the traps are sent.
UDP Port—Enter the UDP port used to for notifications on the recipient
device.
Notification Type—Select whether to send traps or informs. If both are
required, two recipients must be created.
Timeout—Enter the amount of time (seconds) the device waits before re-
sending informs/traps. Timeout: Range 1-300, default 15
Retries—Enter the number of times that the device resends an inform
request. Retries: Range 1-255, default 3
User Name—Select from the drop-down list the user to whom SNMP
notifications are sent. In order to receive notifications, this user must be
defined on the SNMP User page, and its engine ID must be remote.
Security Level—Select how much authentication is applied to the packet.
NOTE The Security Level here depends on which User Name was
selected. If this User Name was configured as No Authentication, the
Security Level is No Authentication only. However, if this User Name has
assigned Authentication and Privacy on the User page, the security level
on this screen can be either No Authentication, or Authentication Only, or
Authentication and Privacy.
The options are:

Table of Contents

Other manuals for Cisco SG500-52P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG500-52P and is the answer not in the manual?

Cisco SG500-52P Specifications

General IconGeneral
ModelSG500-52P
Ports52
PoE Ports48
PoE+Yes
Switching Capacity104 Gbps
LayerLayer 3
Power over Ethernet (PoE)Yes
Rack MountableYes
VLAN SupportYes
ManageableYes
Jumbo Frame SupportYes
Power SupplyInternal
Dimensions440 x 44 x 350 mm
MAC Address Table Size16K entries
Operating Temperature0°C to 50°C
Storage Temperature-20 to 70°C (-4 to 158°F)
Relative Humidity10% to 90%, non-condensing