Administration: Stack Management
Unit Failure in Stack
Cisco 500 Series Stackable Managed Switch Administration Guide Release 1.3 68
5
The following shows what happens when a user-assigned, master-enabled unit
with Unit ID 1 joins a stack that already has a master unit with user-assigned unit ID
1. The newer Unit 1 does not join the stack and is shutdown.
User-assigned Master-enabled Unit
Unit Failure in Stack
Failure of Master Unit
If the Master fails, the backup unit takes over the master role and continues to
operate the stack normally.
In order for the backup to be able to take the place of the master, both units
maintain a warm standby at all times. In warm standby, the master and its backup
units are synchronized with the static configuration (contained in both the Startup
and Running configuration files). Backup configuration files are not synchronized.
The backup configuration file remains on the previous master.
Dynamic process-state information, such as the STP state table, dynamically-
learned MAC addresses, dynamically-learned Smartport types, MAC Multicast
tables, LACP, and GVRP are not synchronized.
When a master is being configured, it synchronizes the backup immediately.
Synchronization is performed as soon as a command is executed. This is
transparent.

Table of Contents

Other manuals for Cisco SG500-52P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG500-52P and is the answer not in the manual?

Cisco SG500-52P Specifications

General IconGeneral
ModelSG500-52P
Ports52
PoE Ports48
PoE+Yes
Switching Capacity104 Gbps
LayerLayer 3
Power over Ethernet (PoE)Yes
Rack MountableYes
VLAN SupportYes
ManageableYes
Jumbo Frame SupportYes
Power SupplyInternal
Dimensions440 x 44 x 350 mm
MAC Address Table Size16K entries
Operating Temperature0°C to 50°C
Storage Temperature-20 to 70°C (-4 to 158°F)
Relative Humidity10% to 90%, non-condensing