Creating XML Provisioning Scripts
Data Types
Provisioning Guide for Cisco SPA100 and SPA200 Series Analog Telephone Adapters 34
2
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60s
Number of Segments = 4
Segment 1: On=0.2s, Off=0.2s
Segment 2: On=0.2s, Off=0.2s
Segment 3: On=0.2s, Off=0.2s
Segment 4: On=1.0s, Off=4.0s
Total Ring Length = 60s
FreqScript—A mini-script that specifics the frequency and level
parameters of a tone. Up to 127 characters. Syntax:
F
1
@L
1
[,F
2
@
L2
[,F
3
@L
3
[,F
4
@L
4
[,F
5
@L
5
[,F
6
@L
6
]]]]], where F
1
–F
6
are frequency in
Hz (unsigned integers only) and L
1
–L
6
are corresponding levels in dBm (with
up to 1 decimal places). White spaces before and after the comma are
allowed (but not recommended).
Example 1—Call Waiting Tone:
440@-10
Number of Frequencies = 1
Frequency 2 = 440 Hz at –10 dBm
Example 2—Dial Tone:
350@-19,440@-19
Number of Frequencies = 2
Frequency 1 = 350 Hz at –19 dBm
Frequency 2 = 440 Hz at –19 dBm
ToneScript—A mini-script that specifies the frequency, level and cadence
parameters of a call progress tone. May contain up to 127 characters.
Syntax: FreqScript;Z
1
[;Z
2
]. The section Z
1
is similar to the S
1
section in a
CadScript except that each on/off segment is followed by a frequency

Table of Contents

Other manuals for Cisco SPA100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SPA100 Series and is the answer not in the manual?

Cisco SPA100 Series Specifications

General IconGeneral
BrandCisco
ModelSPA100 Series
CategoryAdapter
LanguageEnglish

Related product manuals