5-33
Cisco VG248 Analog Phone Gateway Software Configuration Guide
OL-1209-02
Chapter 5 Integrating Cisco CallManager with Voice Mail Systems Using SMDI
Verifying and Troubleshooting the SMDI Connection
SMDI Required Async 1
link has gone
down
Certain SMDI configuration
items require the use of one
or both Async ports. For
example, if the Number of
SMDI ports is greater than
0, Async 1 must be active. If
Forward MWIs to Async 2
is enabled, Async 2 should
be up.
If a required Async port either fails to
come up when the box starts up or
goes down at some point during its
operation, the VG248 generates these
messages.
Check the cables on the Async 1 and
Async 2 ports to verify that they are
still connected.
SMDI Required Async 1
link has not come
up
SMDI Required Async 2
link has gone
down
SMDI Required Async 2
link has not come
up
SMDI Async 1 now
active
These messages indicate
that the VG248 has detected
that it is now connected to
another system via the
indicated Async port, or the
connection has gone down.
These messages are informational
only.
SMDI Async 2 now
active
SMDI Async 1 now
inactive
SMDI Async 2 now
inactive
Table 5-5 SMDI Errors and Warnings Explanation (continued)
System Message Explanation Action