SM-A20758-A/3 1. PRODUCT OVERVIEW
16 2020-10-06
Parameter and commands
Common specification
Index
Sub
index
Item
Value
Access
Data
Length
Format
0x0002
0
System Command
Refer to the "Table 1"
W
1 byte
UInteger8
0x000C
0
Device Access Locks
0x0000 No lock
0x0001 Parameter lock
0x0002 Data storage lock
R
2 byte
Record
0x0020
0
Error Count
0
R
2 byte
UInteger16
0x0024
0
Device Status
0
R
1 byte
UInteger8
0x0025
0
Detailed Devices Status
Refer to the "Diagnosis"
R
33 byte
Array of 3
Octet string
R: read, W: write, R / W: read / write
Table 1 System Command
Value
Command
Description
0x82
Restore Factory Settings
Set the setting value to the shipping state.