Do not rotate the M12 connector.
The L type cable connector does note rotate. Never turn it.
Turn off the power before inserting or removing the M12 connector.
Be sure to turn off the power before inserting or removing the M12 connector.
Always hold the connector when inserting or removing the M12 connector.
Do not pull on the cable.
When fitting the M12 connector, align the convex part of the main body side connector
terminal with the concave part of the cable connector terminal.
After inserting it securely, hold the knurled part and tighten it clockwise so as not to damage the
thread.
Be careful not to over-screw the connector.
If the connector is screwed excessively, the connector on the main unit may be damaged.
Recommended torque: 0.4 to 0.49 N · m
Hold the M12 connector firmly so that it faces up or sideways when inserting it.
The rotating mechanism of the Connector housing allows a 90-degree rotation.
• EVD-1000 Series
• EVD-3000 Series