SM-A20758-A/3 1. PRODUCT OVERVIEW
18 2020-10-06
Index
Sub
index
Item
Value
Data
storage
Access
Data
length
Format
0x0112
0
Preset memory 3
0
Setting range: Depends
on the pressure range.
Y
R/W
2 byte
Integer16
0x0113
0
Preset memory 4
0
Setting range: Depends
on the pressure range.
Y
R/W
2 byte
Integer16
0x0114
0
Preset memory 5
0
Setting range: Depends
on the pressure range.
Y
R/W
2 byte
Integer16
0x0115
0
Preset memory 6
0
Setting range: Depends
on the pressure range.
Y
R/W
2 byte
Integer16
0x0116
0
Preset memory 7
0
Setting range: Depends
on the pressure range.
Y
R/W
2 byte
Integer16
0x0117
0
Preset memory 8
0
Setting range: Depends
on the pressure range.
Y
R/W
2 byte
Integer16
0x0118
0
Unit change
Note 1
0 kPa
1 psi
2 bar
Y
R/W
2 byte
UInteger16
0x0119
0
Position decimal point of
data
1 First digit
2 Second digit
3 Third digit
R
2 byte
UInteger16
0x011A
0
Operation while
communication error
occurred
Note 2
0: HOLD
1 CLEAR
Y
R/W
2 byte
UInteger16
R: read, W: write, R / W: read / write
Default value
Note 1 "1 (psi)" and "2 (bar)" cannot be set when the unit change none type ( Symbol
d
: Blank ) is selected.
Note 2 The operation while communication error occurred is as indicated in Table 1.
Table 1 Operation at communication error
State
Cause
Operation at communication error
Operation at error recovery
Normal mode
Preset mode
Direct mode
Normal mode
Preset mode
Direct mode
C/Q line
disconnection
(Communication
error)
HOLD
setting
Controlled
pressure is
held in
Process Data
Out set value
before an error
occurrence.
Controlled
pressure is
held in Preset
set value
before an
error
occurrence.
Controlled
pressure is
controlled
with Direct set
value.
Controlled
pressure is
controlled with
Process Data
Out set value.
Controlled
pressure is
controlled
with Preset
set value.
Controlled
pressure is
controlled
with Direct set
value.
CLEAR
setting
Pressure
control: 0
Pressure
control: 0
Controlled
pressure is
controlled
with Direct set
value.
Controlled
pressure is
controlled with
Process Data
Out set value.
Controlled
pressure is
controlled
with Preset
set value.
Controlled
pressure is
controlled
with Direct set
value.
*Communication error is defined that Process Data Status is invalid state.
*HOLD/CLEAR/OPEN is the switch for controlling the operation when an error occurrence in the communication function.
They can be set using "On-request Data" in IO-Link communication.