SM-A20758-A/3 3. USAGE
43 2020-10-06
How to operation (IO-Link communication)
<Parameter settings>
Standard setting for proportional value
Index: Write "0: OFF" to 0x010B.
Increases proportional value setting
Index: Write "1: Increases proportional
value" to 0x010B.
Decreases proportional value setting
Index: Write "2: Decreases proportional
value" to 0x010B.
Index: Write " set level " to 0x010C.
Index
Sub
Index
Item
Value
0x010B
0
Proportional value
setting
0: OFF
1: Increases proportional value
2: Decreases proportional
value
0x010C
0
Setting level for the
"Decreases
proportional value"
1 to 10
Parameter and Command