SM-A20758-A/3 3. USAGE
49 2020-10-06
[Confirmation]
Process Data IN
The controlled pressure, start/stop status, input setting, and set pressure can be checked with the
Process Data IN.
The current set pressure should be checked with the "Set value for pressure" of the Process Data IN.
When the "Start/Stop" bit of Process Data IN is set to "0" (Stop) and the "Input setting" is not set
to "0" (Normal Mode), the pressure is not controlled even when the "Set value for pressure" of
the Process Data OUT is set.
PD
PD0
PD1
Bit
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
MSB
LSB
Data name
Set pressure: The value of the "Set value for pressure" of the Process Data OUT is displayed here.
PD
PD2
PD3
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MSB
LSB
Data name
Controlled pressure: EVD’s controlled pressure value is displayed here.
PD
PD4
PD5
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-
-
-
-
-
-
-
-
-
-
-
-
0
0
-
1
Data name
Error
Warning
-
-
-
Switch
output
MSB
LSB
Input setting
-